詳細介紹
性能與特點
·系統設有電磁閥可加裝氣動調壓閥,對氣源進行精確控制,與潤滑液充分混合霧化,減少機械*之損耗,冷卻潤滑效果更佳。
·a .數顯控制:冷卻潤滑時間和間歇時間均可調整。(內般有鎖鍵功能,可鎖定設置后的潤滑和間歇系統時固可設定,“L U B"潤滑時:也設有斷電記憶功能,如工作時間設定1 6秒工作到1 4秒斷電了,下次通電可以繼續按1 4秒開始計時 1 -9 9 9(秒),“INT"間歇:1 - 9 9 9(秒)特殊要求可定制
·b . P L C控制:冷卻潤滑時間和間歇時間由外部P L C控制
·c .無控制:冷卻潤滑時和間歇時間無需控制
·設有液位開關、當冷卻潤滑液不足時蜂鳴器會發出報警信號、并將異常信號輸出。(數顯控制器液位不足顯示E R O )。
·面板指示燈可顯示出潤滑和間歇狀態
·系統建議使用氣壓為0 . 4 - 0 . 6 M P a
·默認液體和氣管直徑6 m m
·配合(M P V型)自吸式冷卻潤滑噴霧器使用。
Performance and Characteristics
· the system is equipped with a solenoid valve that can be equipped with a pneumatic pressure
regulating valve to precisely control the air source and fully atomize it with lubricating fluid to
reduce the loss of mechanical tools and achieve better cooling and lubrication effect.
·a. Digital display control: adjustable cooling and lubrication time and intermittent time. "LUB"
lubrication: also has a power failure memory function, such as the working time set 16 seconds
to 14 seconds of work, the next power can continue to press 14 seconds start timing 1-999
(seconds), "INT" intermittent: 1-999 (seconds) special requirements can be customized
· b.plc control: cooling and lubrication time and intermittent time are controlled by external PLC
·c. No control: no control is required for cooling and lubrication and intermittent time· with liquid
level switch, the buzzer will send out alarm signal and output abnormal signal when the cooling
lubricant is insufficient. Digital display controller liquid level is insufficient to show ERO.
· the indicator light on the panel can show lubrication and intermittent state
· air pressure of 0.4-0.6mpa is recommended for the system
· default diameter of liquid and trachea is 6mm
· suitable for use with (MPV) self-priming cooling and lubricating sprayer.